Renderguard Gold is a high specification plaster additive that forms an integral part of the Safeguard damp- proofing system.Benefits
Properties
Appearance Yellow/gold liquid Size(s) & Packaging 5 liter and 25 liter drums Coverage 1 litre of concentrate is sufficient for 7 m2 of render at 12 mm thickness Storage Store in a cool, well ventilated area. Keep container tightly closed. Protect from frost. Store out of direct sunlight Shelf Life 12 monthsApplication Information
Preparation
1. Timber skirtings, architraves etc., should be removed a outlined in the survey report/specification.
2. Remove plaster back to masonry to the height specified in the survey report/specification. This height should be no less than 1 metre, or 500 mm above the maximum level of visual rising dampness and/or salt contaminated plaster.
3. Rake out all mortar joints to a depth of 15 mm. This is important in order to help resist the natural shrinkage of new cement renders.
4. Remove any timber fixing grounds that are present in the masonry.
Application
To create the gauging solution, mix 1 part Renderguard Gold with 24 parts water. All water should be fresh, clean and free from oil or other organic contaminants.
First Coat
Prepare 3 parts sand and 1 part cement using the dilute Renderguard Gold solution prepared above. The sand should be specified as washed, sharp sand, loam free which satisfies British Standard BS882:1992 “M” Grading.
Use the minimum Renderguard Gold gauging solution to ensure a dense coat. As a guide, no more than 8 litres should be used for every 50 kg of dry mix. Compact the resulting mix well into raked out joints, and render to give an overall thickness of 12 mm. Do not over-trowel. When the cement achieves a first set, then scratch to form a key.
Second Coat
The mix is as for the first coat except that water is used instead of Renderguard Gold solution. This is applied as a further 12 mm coat, giving a total thickness of 24 mm for both coats. This coat should be applied before the first coat has finally set in order to obtain a satisfactory adhesion between the two coats. Scratch the surface to form a key. Do not over-trowel.
Finishing Coat
This should consist of a 3 mm layer of gypsum skim finish or similar finish. Other finishes are acceptable provided that they are porous. Do not polish.
No decoration should take place for at least 6 weeks after treatment (or until the wall has dried out).
25litre
QUANTITY: 25litre
COVERAGE: 175m2
VAT: 290.22
5litre
QUANTITY: 5litre
COVERAGE: 35m2
VAT: 73.96
R440.00 – R1,640.09Price range: R440.00 through R1,640.09
Package and Weight :
5L = 5kg
25L = 25kg
Renderguard Gold is a high specification plaster additive that forms an integral part of the Safeguard damp- proofing system.
Benefits:
Improves adhesion of slurry coats and
sand/cement mixes
Increases resistance to salt efflorescence
Improves workability
Increases flexibility of cement-based materials
Enhances response to thermal movements
Dimensions:
5L – 13cmx 18cm x 28cm
25L – 25m x 29cm x 48cm
Pack Size:
5L – Drum
25L – Drum





PRODUCT GUARANTEE
Polyurethane Roofing – SG PU280
Polyurethane Foundation – SG PU610
Joint Sealant – SG Flex20
Bitumen Roofing – 4mm Torch-on membrane
Polyurethane Undertile Showers / Balconies – SG PU610
Cementitious Undertile Showers/Balconies – Latseal Slurry

Polyurethane Roofing – SG PU280
Polyurethane Foundation – SG PU610
Joint Sealant – SG Flex20
Bitumen Roofing – 4mm Torch-on membrane
Polyurethane Undertile Showers / Balconies – SG PU280
Waterproofing of roofs, basements, etc. shall be laid under appropriate manufacturer guarantees supplemented
by a contractor workmanship guarantee. Waterproofing to flat roofs shall be laid with a minimum fall to outlets of
1:80 and include all outlets, etc.Waterproof of external basment walls shall take into account the definition of dry and wet sides as per SANS 10021: 2006 6.15.2 and 6.1.5.3 and provide one or two layer membrane systems as
appropriate descriptions of sheets or membrane waterproofing shall be deemed to include all labour costs.
Apply Safeguard SG720″ primer to prepared surfaces, followed by two coats of “Safeguard SG280” waterproofing
polyurethane and one coat of SG PU440 with SG PU Fabric on horizontal and vertical joints.
Apply Safeguard SG720″ primer to prepared surfaces, followed by two coats of “Safeguard SG280” waterproofing
polyurethane and one coat of SG PU450 with SG PU Fabric on horizontal and vertical joints.
Thoroughly clean and prepare all external walls from foundation to 2 brick courses above finished ground level as per Safeguard Method Statement for Surface Preparation.
Apply one coat of Safeguard SG 720 Primer to the walls by spray, roller or brush and allow to dry.
Apply two coats of Safeguard SG PU 610 by spray, roller or brush. If applying by spray, dilute with 5% MEK. Allow the first coat to dry overnight. A third coat should be applied where “Wet” sites are encountered as per SANS 10021:2006 6.1.5.3
Protect membrane with soft board or dimpled membrane prior to backfill.
Equivalent performance-related products may be supplied.
Thoroughly clean and prepare all external walls from foundation to 2 brick courses above finished ground level, removing all dirt, dust, grime grease and any unnecessary mortar,
Apply one coat of Polyurethane Primer to the walls and allow to dry.
Apply two coats of Polyurethane waterproofing membrane to a DFT of 1-2mm. The membrane should accommodate temperatures from -30? to +90?C and have a minimum elasticity of 600% with a Shore A hardness of 60 or greater and a Tensile strength of 4N/mm? or greater. Allow the first coat to dry overnight. A third coat should be applied where “Wet” sites are encountered as per SANS 10021:2006 6.1.5.3
Protect membrane with soft board or dimpled membrane prior to backfill.
Thoroughly clean and prepare the surface, as per Safeguard Method Statement for Surface Preparation.
Apply one coat of Safeguard solvent-based Bitumen Primer to the surface ensuring full coverage without any “ponding” of primer on the surface.
Allow to dry and heat-fuse one layer of Safeguard Euro Gecko 4mm APP single re-inforced Bitumen Membrane to the primed surface, lapping all side walls and dressing into and around outlets and upstands.
Provide 100mm side laps and 150mm end laps to adjoining rolls of membrane, ensuring that laps are properly “bled”.
Suitable performance-related products are acceptable.
5-7 days after application of the Bitumen Membrane, thoroughly clean the surface of the membrane and apply 2 coats of Safeguard Bitumen Aluminium paint to the membrane using a brush, roller or spray.
Equivalent products are acceptable.
Thoroughly clean and prepare the surface, removing all laitance, dust, dirt, grime and grease.
Apply one coat of solvent-based Bitumen Primer to the surface ensuring full coverage without any “ponding” of primer on the surface.
Allow to dry and heat-fuse one layer of 4mm APP single re-inforced Bitumen Membrane to the primed surface, lapping all side walls and dressing into and around outlets and upstands.
Provide 100mm side laps and 150mm end laps to adjoining rolls of membrane, ensuring that laps are properly “bled”.
5-7 days after application of the Bitumen Membrane, thoroughly clean the surface of the membrane and apply 2 coats of Bitumen Aluminium paint to the membrane using a brush, roller or spray.
Thoroughly clean shower walls and floor, removing all loose dirt, mortar, grime and grease. Walls should not be plastered.
Apply a coat of Safeguard Latseal Slurry mixed with Bondaid to the walls and floor, embedding a non-woven polypropylene membrane into the slurry at all joints.
Allow to cure overnight and apply a further coat of Safeguard slurry to the entire area.
At the joint with the outlet, an expandable polyurethane sealant should be applied to cover both surfaces. This should be allowed to cure, together with the slurry before application of any tiles/mosaics.
Equivalent products are acceptable.
Thoroughly clean shower walls and floor, removing all loose dirt, mortar, grime and grease. Walls should not be plastered.
Apply a coat of cementitious waterproof slurry mixed with bonding liquid to the walls and floor, embedding a non-woven polypropylene membrane into the slurry at all joints.
Allow to cure overnight and apply a further coat of slurry to the entire area.
At the joint with the outlet, an expandable polyurethane sealant should be applied to cover both surfaces. This should be allowed to cure, together with the slurry before application of any tiles/mosaics.